{"id":2740,"date":"2025-10-24T09:33:35","date_gmt":"2025-10-24T01:33:35","guid":{"rendered":"https:\/\/ceshi.tfngw.com\/?page_id=2740"},"modified":"2026-01-21T19:11:33","modified_gmt":"2026-01-22T03:11:33","slug":"t3000a-10-gigabit-ethernet-tester","status":"publish","type":"page","link":"https:\/\/www.tfngj.com\/fr\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/","title":{"rendered":"T3000A 10 Gigabit Ethernet Tester"},"content":{"rendered":"<div class=\"wp-block-cover alignfull is-light wp-duotone-unset-1\" style=\"border-radius:0px;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:clamp(3.615rem, 3.615rem + ((1vw - 0.2rem) * 4.856), 7.5rem);min-height:469px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1280\" class=\"wp-block-cover__image-background wp-image-2167 size-full\" alt=\"\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp\" data-object-fit=\"cover\" srcset=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp 2560w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-300x150.webp 300w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-1024x512.webp 1024w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-768x384.webp 768w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-1536x768.webp 1536w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-2048x1024.webp 2048w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-18x9.webp 18w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-600x300.webp 600w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\" style=\"background-color:#349aca\"><\/span><div class=\"wp-block-cover__inner-container has-global-padding is-layout-constrained wp-container-core-cover-is-layout-ad1af2a0 wp-block-cover-is-layout-constrained\"><h1 class=\"wp-block-heading alignfull has-text-align-center has-neutral-0-color has-text-color has-link-color has-5-x-large-font-size wp-elements-b6d9bd2fb7b267a4505ea166bebee6ce\" style=\"margin-right:0;margin-left:var(--wp--preset--spacing--small);text-transform:capitalize\" id=\"t3000a-ethernet-tester\">T3000A Testeur Ethernet<\/h1>\n\n\n\n<p class=\"has-text-align-center has-neutral-0-color has-text-color has-link-color has-large-font-size wp-elements-0734d17205deefcd889595e5263b55fc\" style=\"margin-top:var(--wp--preset--spacing--x-small)\">Testeur portable de 10 gigabits, permettant des tests \u00e0 plein d\u00e9bit de 10M \u00e0 10G, facilitant le d\u00e9ploiement et la maintenance de r\u00e9seaux \u00e0 haut d\u00e9bit.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-content-justification-center is-layout-constrained wp-container-core-group-is-layout-df757ecc wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:calc( 0.5 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)));padding-right:var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal));padding-bottom:calc( 0.5 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)));padding-left:var(--wp--style--root--padding-left, var(--wp--custom--gap--horizontal))\">\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:calc( 0.25 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)))\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/www.tfngj.com\/fr\/\">Accueil<\/a><\/span> &gt; <span><a href=\"https:\/\/www.tfngj.com\/fr\/ethernet-testers\/\">Testeurs Ethernet<\/a><\/span> &gt; <span class=\"breadcrumb_last\" aria-current=\"page\">T3000A 10 Gigabit Ethernet Tester<\/span><\/span><\/div><\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-b9f7452e wp-block-columns-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--x-large)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:40%\"><h2 class=\"wp-block-heading has-4-x-large-font-size\" id=\"highlights\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#2588cc\" class=\"has-inline-color\">Points forts<\/mark><\/h2>\n\n\n\n<style>\n.tfn-slider {\n  position: relative;\n  max-width: 100%;\n  overflow: hidden;\n}\n\n.tfn-slides {\n  display: flex;\n  transition: transform 0.5s ease;\n}\n\n.tfn-slide {\n  min-width: 100%;\n  cursor: zoom-in; \/* \u7ed9\u7528\u6237\u660e\u786e\u63d0\u793a\uff1a\u53ef\u70b9\u51fb\u67e5\u770b *\/\n}\n\n.tfn-slide img {\n  width: 100%;\n  height: auto;\n  display: block;\n}\n\n\/* \u7bad\u5934 *\/\n.tfn-arrow {\n  position: absolute;\n  top: 50%;\n  transform: translateY(-50%);\n  background: rgba(0,0,0,0.5);\n  color: #fff;\n  border: none;\n  padding: 10px;\n  cursor: pointer;\n  z-index: 2;\n}\n.tfn-arrow.prev { left: 10px; }\n.tfn-arrow.next { right: 10px; }\n\n\/* \u5706\u70b9 *\/\n.tfn-dots {\n  text-align: center;\n  margin-top: 10px;\n}\n.tfn-dot {\n  display: inline-block;\n  width: 10px;\n  height: 10px;\n  background: #ccc;\n  border-radius: 50%;\n  margin: 0 5px;\n  cursor: pointer;\n}\n.tfn-dot.active {\n  background: #333;\n}\n<\/style>\n\n<div class=\"tfn-slider\" id=\"tfnSlider\">\n  <div class=\"tfn-slides\">\n\n    <!-- \u7b2c\u4e00\u5f20\u56fe\u7247\n         \u70b9\u56fe \u2192 \u65b0\u6807\u7b7e\u9875\u6253\u5f00 image1.jpg\uff08\u539f\u6bd4\u4f8b\uff09 -->\n    <div class=\"tfn-slide\">\n      <a href=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/1-1.jpg\" target=\"_blank\">\n        <img decoding=\"async\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/1-1.jpg\" alt=\"Testeur Ethernet\">\n      <\/a>\n    <\/div>\n\n    <!-- \u7b2c\u4e8c\u5f20\u56fe\u7247 -->\n    <div class=\"tfn-slide\">\n      <a href=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1.jpg\" target=\"_blank\">\n        <img decoding=\"async\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1.jpg\" alt=\"Testeur ethernet 10-gigabits\">\n      <\/a>\n    <\/div>\n\n    <!-- \u7b2c\u4e09\u5f20\u56fe\u7247 -->\n    <div class=\"tfn-slide\">\n      <a href=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/3-2.jpg\" target=\"_blank\">\n        <img decoding=\"async\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/3-2.jpg\" alt=\"Testeur Ethernet\">\n      <\/a>\n    <\/div>\n\n    <!-- \u7b2c\u56db\u5f20\u56fe\u7247 -->\n    <div class=\"tfn-slide\">\n      <a href=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-8.jpg\" target=\"_blank\">\n        <img decoding=\"async\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-8.jpg\" alt=\"Testeur Ethernet\">\n      <\/a>\n    <\/div>\n\n  <\/div>\n\n  <button class=\"tfn-arrow prev\">\u276e<\/button>\n  <button class=\"tfn-arrow next\">\u276f<\/button>\n<\/div>\n\n<div class=\"tfn-dots\" id=\"tfnDots\"><\/div>\n\n<script>\n(function() {\n  const slider = document.getElementById('tfnSlider');\n  const slides = slider.querySelector('.tfn-slides');\n  const slideCount = slides.children.length;\n  const dotsContainer = document.getElementById('tfnDots');\n  let index = 0;\n\n  function updateSlider() {\n    slides.style.transform = 'translateX(' + (-index * 100) + '%)';\n    document.querySelectorAll('.tfn-dot').forEach((dot, i) => {\n      dot.classList.toggle('active', i === index);\n    });\n  }\n\n  for (let i = 0; i < slideCount; i++) {\n    const dot = document.createElement('span');\n    dot.className = 'tfn-dot' + (i === 0 ? ' active' : '');\n    dot.addEventListener('click', () => {\n      index = i;\n      updateSlider();\n    });\n    dotsContainer.appendChild(dot);\n  }\n\n  slider.querySelector('.prev').onclick = () => {\n    index = (index - 1 + slideCount) % slideCount;\n    updateSlider();\n  };\n\n  slider.querySelector('.next').onclick = () => {\n    index = (index + 1) % slideCount;\n    updateSlider();\n  };\n\n  setInterval(() => {\n    index = (index + 1) % slideCount;\n    updateSlider();\n  }, 5000);\n})();\n<\/script>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:60%\"><ul style=\"margin-right:0;--plover--style--block-gap:0;\" class=\"wp-block-list is-style-check-ghost\">\n<li>Couverture compl\u00e8te : Un seul appareil permet d'effectuer des tests de d\u00e9bit sur toute la gamme, de 10M \u00e0 10G, ce qui permet d'\u00e9viter les doubles investissements dus aux mises \u00e0 niveau du r\u00e9seau.<\/li>\n\n\n\n<li>Il prend en charge 16 flux de donn\u00e9es simultan\u00e9s, ce qui permet de simuler les pressions commerciales r\u00e9elles et d'\u00e9valuer avec pr\u00e9cision les performances du r\u00e9seau.<\/li>\n\n\n\n<li>Tests standard int\u00e9gr\u00e9s tels que RFC2544, Y.1564, BERT, MPLS et IPv6, avec ex\u00e9cution automatis\u00e9e en un clic pour am\u00e9liorer l'efficacit\u00e9 des tests.<\/li>\n\n\n\n<li>Prise en charge de la d\u00e9tection de bouclage L1 - L4 et de la surveillance de la p\u00e9n\u00e9tration en ligne, permettant de diagnostiquer les d\u00e9fauts sans interrompre les services.<\/li>\n\n\n\n<li>\u00c9cran tactile haute r\u00e9solution de 7 pouces combin\u00e9 \u00e0 une fonction de contr\u00f4le \u00e0 distance par PC, adapt\u00e9 \u00e0 une utilisation dans divers environnements tels que les laboratoires et les sites.<\/li>\n\n\n\n<li>La batterie lithium int\u00e9gr\u00e9e de grande capacit\u00e9 offre 4 heures de fonctionnement continu et est livr\u00e9e avec une mallette de transport, ce qui la rend adapt\u00e9e aux op\u00e9rations sur le terrain.<\/li>\n<\/ul>\n\n\n\n<p>Le T3000A prend en charge les tests des ports \u00e9lectriques 10M\/100M\/1000M, des ports optiques 1,25G et des doubles ports optiques 10G SFP+. Int\u00e9grant la g\u00e9n\u00e9ration de trafic, l'analyse de protocole, les tests de performance et le diagnostic des d\u00e9fauts, il offre des capacit\u00e9s de test compl\u00e8tes pour RFC2544, Y.1564, BERT, MPLS et VLAN Q - in - Q. Il convient \u00e0 la mise en service de r\u00e9seaux 10G et \u00e0 la localisation de d\u00e9fauts complexes.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.tfngj.com\/fr\/contact-us\/\">Demande de devis<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading alignwide has-text-align-left has-4-x-large-font-size\" style=\"padding-left:0rem\" id=\"specifications\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#2588cc\" class=\"has-inline-color\">Sp\u00e9cifications<\/mark><\/h2>\n\n\n\n<figure class=\"wp-block-table alignwide is-style-stripes\"><table class=\"has-background\" style=\"background-color:#bae0f7\"><tbody><tr><td>Interfaces optiques<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Deux interfaces GigE<\/td><\/tr><tr><td><\/td><td class=\"has-text-align-center\" data-align=\"center\">1000Base-SX<\/td><td>1000Base-LX<\/td><td>1000Base-ZX<\/td><\/tr><tr><td>Longueur d'onde (nm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">850<\/td><td>1310<\/td><td>1550<\/td><\/tr><tr><td>Type de laser\/connecteur\/<br>type d'\u00e9metteur-r\u00e9cepteur<\/td><td class=\"has-text-align-center\" data-align=\"center\">VCSEL\/LC\/SFP<\/td><td>FP\/LC\/SFP<\/td><td>DFB\/LC\/SFP<\/td><\/tr><tr><td>Interface \u00e9lectrique<\/td><td class=\"has-text-align-center\" data-align=\"center\">Deux ports 10\/100BaseT half\/full-duplex et 1000BaseT full-duplex, <br>avec options de c\u00e2ble droit ou crois\u00e9<\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td class=\"has-text-align-center\" data-align=\"center\">10BaseT<\/td><td>100BaseT<\/td><td>1000BaseT<\/td><\/tr><tr><td>Connecteurs<\/td><td class=\"has-text-align-center\" data-align=\"center\">RJ-45<\/td><td>RJ-45<\/td><td>RJ-45<\/td><\/tr><tr><td colspan=\"4\"><strong>\u00c9l\u00e9ments du test<\/strong><\/td><\/tr><tr><td>Y.1564<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Testez la configuration et les services du r\u00e9seau conform\u00e9ment \u00e0 la norme ITU-T Y.1564. Utilisez le bouclage \u00e0 distance ou le mode double testeur pour obtenir des r\u00e9sultats bidirectionnels.<\/td><\/tr><tr><td>RFC2544<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Mesurer le d\u00e9bit, la transmission back-to-back, la perte de trame et la latence comme sp\u00e9cifi\u00e9 dans la RFC 2544. Taille de la trame : D\u00e9finie par la RFC, configurable par l'utilisateur de 1 \u00e0 7.<\/td><\/tr><tr><td>Test d'erreur BERT<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Prend en charge les couches 1 \u00e0 4 avec ou sans VLAN Q-in-Q.<\/td><\/tr><tr><td>Mode de passage<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Segmente le trafic entre le r\u00e9seau du fournisseur de services et l'\u00e9quipement des locaux du client.<\/td><\/tr><tr><td>Temps d'interruption du service (SDT)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Inclut des statistiques, notamment le temps de panne minimum, le temps de panne maximum, le dernier temps m\u00e9dian, le temps de panne moyen, le temps de panne total et les seuils de r\u00e9ussite\/\u00e9chec.<\/td><\/tr><tr><td>G\u00e9n\u00e9ration de flux multiples<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Permet de transmettre et de contr\u00f4ler jusqu'\u00e0 16 flux de donn\u00e9es sur les r\u00e9seaux Ethernet et IP.<\/td><\/tr><tr><td>G\u00e9n\u00e9ration et suivi du trafic<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Capable de g\u00e9n\u00e9rer et de surveiller les flux de trafic Ethernet et IP, et capable de fa\u00e7onner le trafic sur la base des statistiques suivantes : d\u00e9bit, perte de trame, s\u00e9quen\u00e7age des trames, gigue des paquets, latence, taille des trames, type de trafic et surveillance des flux.<\/td><\/tr><tr><td>Empilement de VLAN<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Capable de g\u00e9n\u00e9rer des flux de trafic avec jusqu'\u00e0 deux couches VLAN (y compris les VLAN \u00e9tiquet\u00e9s IEEE802.1ad Q-in-Q) \u00e0 n'importe quelle couche VLAN empil\u00e9e, en utilisant soit l'ID VLAN, soit la priorit\u00e9 VLAN.<\/td><\/tr><tr><td>Tests IPv6<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Y compris BERT, RFC2544, g\u00e9n\u00e9ration et surveillance de flux d'informations, flux d'informations en arri\u00e8re-plan, Smart loopback, Ping et traceroute.<\/td><\/tr><tr><td colspan=\"4\">Indicateurs g\u00e9n\u00e9raux<\/td><\/tr><tr><td>Interface<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Port USB 2.0 ; RJ-45 LAN<\/td><\/tr><tr><td>Stockage<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">8 GO<\/td><\/tr><tr><td>Interface de donn\u00e9es<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">RJ-45\/ USB<\/td><\/tr><tr><td>Affichage<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">\u00c9cran tactile LCD couleur de 7 pouces, 960\u00d7480 <\/td><\/tr><tr><td>Dur\u00e9e de vie de la batterie<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Fonctionnement continu pendant plus de 4 heures<\/td><\/tr><tr><td>Taille<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">282\u00d7186\u00d775mm, 2,9kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-buttons alignwide is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-ghost\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/pdf\/T3000A-Ethernet-Tester.pdf\">T\u00e9l\u00e9charger le manuel<\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-content-justification-center is-layout-constrained wp-container-core-group-is-layout-df757ecc wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:calc( 0.5 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)));padding-right:var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal));padding-bottom:calc( 0.5 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)));padding-left:var(--wp--style--root--padding-left, var(--wp--custom--gap--horizontal))\">\n<div style=\"height:calc( 0.25 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)))\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<h2 class=\"wp-block-heading alignwide has-text-color has-link-color has-4-x-large-font-size wp-elements-05d82ed00a7fc3470e0d80fc5d72fe4c\" style=\"color:#2588cc;margin-top:var(--wp--preset--spacing--x-large)\" id=\"features\">Caract\u00e9ristiques<\/h2>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p class=\"has-text-color has-link-color has-2-x-large-font-size wp-elements-5272613ae2ff822db6607ceb455300fe\" style=\"color:#2588cc\"><strong>Test RFC 2544<\/strong><\/p>\n\n\n\n<p>Le test RFC 2544 \u00e9value les principales mesures de performance Ethernet, notamment le d\u00e9bit, la latence, la perte de trame et les trames back-to-back. Il est largement utilis\u00e9 pour la mise en service des r\u00e9seaux, la v\u00e9rification des services et l'\u00e9talonnage des performances.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"480\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c.png\" alt=\"rfc2544\" class=\"wp-image-5665\" style=\"width:735px;height:auto\" srcset=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c.png 800w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c-300x180.png 300w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c-768x461.png 768w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c-18x12.png 18w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-5c5d7afb wp-block-columns-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--large)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p class=\"has-text-color has-link-color has-2-x-large-font-size wp-elements-d2dc69884a124f4f929638f4ef7b60b8\" style=\"color:#2588cc\"><strong>Test BERT<\/strong><\/p>\n\n\n\n<p>Le test BERT mesure le taux d'erreur sur les bits pendant la transmission des donn\u00e9es, ce qui permet d'identifier les probl\u00e8mes d'int\u00e9grit\u00e9 du signal tels que le bruit, les interf\u00e9rences ou les d\u00e9fauts de la couche physique. Il est essentiel pour la validation des liaisons et les tests de stabilit\u00e9 \u00e0 long terme des r\u00e9seaux.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"480\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c.png\" alt=\"rfc2544\" class=\"wp-image-5665\" style=\"width:735px;height:auto\" srcset=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c.png 800w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c-300x180.png 300w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c-768x461.png 768w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2026\/01\/2544\u6d4b\u8bd5\u7ed3\u679c-18x12.png 18w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-5c5d7afb wp-block-columns-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--large);font-size:clamp(2.671rem, 2.671rem + ((1vw - 0.2rem) * 3.036), 5.1rem);\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66%\"><h2 class=\"wp-block-heading has-2-x-large-font-size\" id=\"main-test-functions\">Principales fonctions de test<\/h2>\n\n\n\n<p style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.281), 1.1rem);\"><strong>Tests de performance :<\/strong> RFC2544 (d\u00e9bit, latence, perte de paquets, back-to-back), configuration du service Y.1564 et tests de qualit\u00e9<br><strong>Test du code d'erreur :<\/strong> supporte les tests BERT L1 \u00e0 L4, y compris PRBS, CJPAT, CRPAT et autres types de codes, injection de fautes en option<br><strong>Prise en charge de protocoles avanc\u00e9s :<\/strong> VLAN Q - in - Q, MPLS (imbrication \u00e0 3 niveaux), IPv6, OAM (option)<br><strong>Simulation et surveillance des services : <\/strong>la g\u00e9n\u00e9ration de flux multiservices, la mise en forme du trafic et la mesure du temps d'interruption du service (SDT)<br><strong>Outils de diagnostic intelligents : <\/strong>d\u00e9couverte de la topologie du r\u00e9seau, bouclage \u00e0 distance, Ping, Trace - route, capture et analyse de paquets<br><strong>Mode de p\u00e9n\u00e9tration :<\/strong> prend en charge la surveillance en ligne \u00e0 un d\u00e9bit de 10M \/ 10G et l'injection de d\u00e9fauts sans affecter les services existants<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:34%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1.jpg\" alt=\"\" class=\"wp-image-2752\" srcset=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1.jpg 800w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1-300x300.jpg 300w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1-150x150.jpg 150w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1-768x768.jpg 768w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1-12x12.jpg 12w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1-600x600.jpg 600w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/5-1-100x100.jpg 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-f7e079e7 wp-block-columns-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--x-large);margin-right:8rem;margin-left:8rem;font-size:clamp(2.111rem, 2.111rem + ((1vw - 0.2rem) * 2.111), 3.8rem);\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:36%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" src=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/pexels-cookiecutter-1148820-1024x684.jpg\" alt=\"\" class=\"wp-image-2434\" srcset=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/pexels-cookiecutter-1148820-1024x684.jpg 1024w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/pexels-cookiecutter-1148820-300x200.jpg 300w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/pexels-cookiecutter-1148820-768x513.jpg 768w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/pexels-cookiecutter-1148820-1536x1026.jpg 1536w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/pexels-cookiecutter-1148820-18x12.jpg 18w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/pexels-cookiecutter-1148820-600x401.jpg 600w, https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/pexels-cookiecutter-1148820.jpg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:64%\"><h3 class=\"wp-block-heading has-2-x-large-font-size\" id=\"application-scenarios\">Sc\u00e9narios d'application<\/h3>\n\n\n\n<p style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.281), 1.1rem);\">Acceptation de la mise en service des couches d'acc\u00e8s et d'agr\u00e9gation 10G Ethernet<br>Interconnexion des centres de donn\u00e9es et v\u00e9rification des performances des services en nuage<br>Surveillance de la qualit\u00e9 de service des r\u00e9seaux IP\/MPLS des op\u00e9rateurs<br>Mise \u00e0 niveau et d\u00e9pannage du r\u00e9seau central de l'entreprise<br>Essais de R&amp;D et de v\u00e9rification pour les fabricants d'\u00e9quipements de r\u00e9seau<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:calc( 0.25 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)))\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading alignwide has-text-align-left has-4-x-large-font-size\" style=\"margin-top:var(--wp--preset--spacing--x-large);margin-bottom:var(--wp--preset--spacing--large);padding-left:0rem\" id=\"product-demo\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#2588cc\" class=\"has-inline-color\">D\u00e9monstration du produit<\/mark><\/h2>\n\n\n\n<div style=\"display: flex; justify-content: center;\">\n  <iframe loading=\"lazy\" width=\"560\" height=\"315\" \n    src=\"https:\/\/www.youtube.com\/embed\/wptnTYYM4s4?si=TTIfGh-QEc3qraH0\" \n    title=\"Lecteur vid\u00e9o YouTube\" frameborder=\"0\" \n    allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" \n    referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen>\n  <\/iframe>\n<\/div>\n\n\n\n<div style=\"height:38px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-aecdc57f wp-block-group-is-layout-constrained\" style=\"background:linear-gradient(135deg,rgb(0,74,173) 0%,rgb(93,224,230) 100%);margin-top:0;margin-bottom:0;padding-top:calc( 0.5 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)));padding-right:var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal));padding-bottom:calc( 0.5 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)));padding-left:var(--wp--style--root--padding-left, var(--wp--custom--gap--horizontal))\">\n<div style=\"height:calc( 0.25 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)))\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:38px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-23441af8 wp-block-group-is-layout-flex\"><h2 class=\"wp-block-heading alignwide has-text-align-center has-4-x-large-font-size\" id=\"real-experiences-with-ethernet-testers\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-neutral-0-color\">Exp\u00e9riences r\u00e9elles avec les testeurs Ethernet<\/mark><\/h2>\n<\/div>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-neutral-0-color has-text-color has-link-color wp-elements-631745007e7497dc3a6b6c17bd89c974 is-layout-flex wp-container-core-columns-is-layout-bb131731 wp-block-columns-is-layout-flex\" style=\"padding-right:var(--wp--preset--spacing--x-small);padding-left:var(--wp--preset--spacing--x-small)\">\n<div class=\"wp-block-column has-global-padding is-layout-constrained wp-container-core-column-is-layout-f3454425 wp-block-column-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--10);padding-right:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10);padding-left:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-group has-global-padding is-content-justification-center is-layout-constrained wp-container-core-group-is-layout-553cd11f wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--medium);margin-bottom:var(--wp--preset--spacing--medium);padding-right:0;padding-left:0\">\n<div class=\"wp-block-group is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-f34c8a65 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-layout-flow wp-container-core-group-is-layout-15eb98a8 wp-block-group-is-layout-flow\"><h3 class=\"wp-block-heading has-text-align-center is-testimonial-name has-neutral-0-color has-text-color has-link-color has-small-font-size wp-elements-45d3e7b658e7a5aba72da25e97ecd3b8\" style=\"line-height:1\" id=\"david-r\">David R.<\/h3>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:0\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-center is-testimonial-review\">\u201cLe <strong>T3000A<\/strong> est devenu mon testeur Ethernet de pr\u00e9dilection pour les projets 10G. Il fournit des r\u00e9sultats pr\u00e9cis et prend en charge toutes les normes cl\u00e9s telles que RFC2544 et Y.1564. L'interface est intuitive et la commutation entre les ports optiques et \u00e9lectriques se fait sans effort. Il est parfait pour l'analyse rapide des d\u00e9fauts et les contr\u00f4les de performance sur le terrain.\u201d<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--10);padding-right:var(--wp--preset--spacing--10);padding-bottom:var(--wp--preset--spacing--10);padding-left:var(--wp--preset--spacing--10)\">\n<div class=\"wp-block-group has-global-padding is-content-justification-center is-layout-constrained wp-container-core-group-is-layout-3e9bf817 wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--medium);margin-bottom:var(--wp--preset--spacing--medium)\">\n<div class=\"wp-block-group is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-f34c8a65 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-layout-flow wp-container-core-group-is-layout-15eb98a8 wp-block-group-is-layout-flow\"><h4 class=\"wp-block-heading has-text-align-center is-testimonial-name has-neutral-0-color has-text-color has-link-color has-small-font-size wp-elements-3b186c06a9285d739ebae7f191455c86\" style=\"line-height:1\" id=\"mark-s\">Mark S.<\/h4>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:0\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-center is-testimonial-review\">\u201cJe suis vraiment impressionn\u00e9 par <strong>Les testeurs ethernet de TFN<\/strong>. Il combine plusieurs modes de test - BERT, MPLS, VLAN et d\u00e9bit - dans une unit\u00e9 compacte. Les r\u00e9sultats sont pr\u00e9cis, l'installation est rapide et le service client de TFN est excellent. Il est id\u00e9al pour l'installation et la maintenance des r\u00e9seaux \u00e0 haut d\u00e9bit\u201d.\u201d<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:38px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:calc( 0.25 * var(--wp--style--root--padding-right, var(--wp--custom--gap--horizontal)))\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-4-x-large-font-size\" id=\"faqs\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#2588cc\" class=\"has-inline-color\">FAQ<\/mark><\/h2>\n\n\n\n<details class=\"wp-block-details has-border-color is-layout-flow wp-block-details-is-layout-flow\" style=\"border-color:#4083ca;border-width:2px;line-height:1.8\" open><summary>Quelles sont les options logistiques que vous proposez ?<\/summary>\n<p>Nous fournissons des solutions logistiques optimis\u00e9es en fonction de l'urgence de votre commande, de sa taille, de son poids et de votre localisation :<\/p>\n\n\n\n<p>International Express : Convient aux \u00e9chantillons, aux commandes urgentes et aux petits envois de moins de 10 kg. Nous travaillons en partenariat avec les meilleurs fournisseurs de services logistiques tels que DHL, FedEx et UPS, offrant un suivi porte-\u00e0-porte.<\/p>\n\n\n\n<p>Fret a\u00e9rien : Convient aux commandes moyennes \u00e0 importantes ou aux \u00e9quipements complets sensibles au facteur temps, offrant un \u00e9quilibre efficace entre co\u00fbt et rapidit\u00e9.<\/p>\n\n\n\n<p>Fret maritime : Convient aux commandes de gros volumes et constitue la m\u00e9thode d'exp\u00e9dition la plus \u00e9conomique. Nous offrons une vari\u00e9t\u00e9 de conditions commerciales, y compris FOB, C&amp;F et CIF.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details has-border-color is-layout-flow wp-block-details-is-layout-flow\" style=\"border-color:#4083ca;border-width:2px\"><summary>Quel est le d\u00e9lai d'ex\u00e9cution ?<\/summary>\n<p>Pour nos produits standard, s'ils sont en stock et pr\u00eats \u00e0 \u00eatre exp\u00e9di\u00e9s, le d\u00e9lai est d'environ 7 \u00e0 10 jours. Pour les produits optionnels, le d\u00e9lai est d'environ 25 \u00e0 30 jours.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details has-border-color is-layout-flow wp-block-details-is-layout-flow\" style=\"border-color:#4083ca;border-width:2px\"><summary>Soutenez-vous la formation en ligne ?<\/summary>\n<p>Oui, nous proposons une formation en ligne. Nous disposons \u00e9galement de vid\u00e9os d'utilisation en anglais pour le F7 OTDR (sur notre site Web). <a href=\"https:\/\/www.youtube.com\/@FateTFN\/\">Cha\u00eene YouTube<\/a>) et des logiciels d'analyse pour nos clients.<\/p>\n<\/details>\n\n\n\n<div style=\"height:59px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Highlights &#10094; &#10095; The T3000A supports testing of 10M\/100M\/1000M electrical ports, 1.25G optical ports, and dual 10G SFP+ optical ports. Integrating traffic generation, protocol analysis, performance testing, and fault diagnosis, it offers comprehensive testing capabilities for RFC2544, Y.1564, BERT, MPLS, and VLAN Q &#8211; in &#8211; Q. Suitable for 10G network commissioning and complex fault [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"parent":1408,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2740","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>TFN T3000A 10 Gigabit Ethernet Tester<\/title>\n<meta name=\"description\" content=\"A Handheld 10 gigabit tester, supporting 10M to 10G full-rate testing, facilitating high-speed network deployment and maintenance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tfngj.com\/fr\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TFN T3000A 10 Gigabit Ethernet Tester\" \/>\n<meta property=\"og:description\" content=\"A Handheld 10 gigabit tester, supporting 10M to 10G full-rate testing, facilitating high-speed network deployment and maintenance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tfngj.com\/fr\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/\" \/>\n<meta property=\"og:site_name\" content=\"Communication Test Expert\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-22T03:11:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1280\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/\",\"url\":\"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/\",\"name\":\"TFN T3000A 10 Gigabit Ethernet Tester\",\"isPartOf\":{\"@id\":\"https:\/\/www.tfngj.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp\",\"datePublished\":\"2025-10-24T01:33:35+00:00\",\"dateModified\":\"2026-01-22T03:11:33+00:00\",\"description\":\"A Handheld 10 gigabit tester, supporting 10M to 10G full-rate testing, facilitating high-speed network deployment and maintenance.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#primaryimage\",\"url\":\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp\",\"contentUrl\":\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tfngj.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ethernet Testers\",\"item\":\"https:\/\/www.tfngj.com\/ethernet-testers\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"T3000A 10 Gigabit Ethernet Tester\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tfngj.com\/#website\",\"url\":\"https:\/\/www.tfngj.com\/\",\"name\":\"TFN-Communication Test Expert\",\"description\":\"Find Perfect Solutions in TFN\",\"publisher\":{\"@id\":\"https:\/\/www.tfngj.com\/#organization\"},\"alternateName\":\"TFN\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tfngj.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tfngj.com\/#organization\",\"name\":\"TFN\",\"url\":\"https:\/\/www.tfngj.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.tfngj.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/09\/\u9ed1logo.png\",\"contentUrl\":\"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/09\/\u9ed1logo.png\",\"width\":939,\"height\":232,\"caption\":\"TFN\"},\"image\":{\"@id\":\"https:\/\/www.tfngj.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.youtube.com\/@FateTFN\/search\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Testeur TFN T3000A 10 Gigabit Ethernet","description":"Testeur portable de 10 gigabits, permettant des tests \u00e0 plein d\u00e9bit de 10M \u00e0 10G, facilitant le d\u00e9ploiement et la maintenance de r\u00e9seaux \u00e0 haut d\u00e9bit.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tfngj.com\/fr\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/","og_locale":"fr_FR","og_type":"article","og_title":"TFN T3000A 10 Gigabit Ethernet Tester","og_description":"A Handheld 10 gigabit tester, supporting 10M to 10G full-rate testing, facilitating high-speed network deployment and maintenance.","og_url":"https:\/\/www.tfngj.com\/fr\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/","og_site_name":"Communication Test Expert","article_modified_time":"2026-01-22T03:11:33+00:00","og_image":[{"width":2560,"height":1280,"url":"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/","url":"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/","name":"Testeur TFN T3000A 10 Gigabit Ethernet","isPartOf":{"@id":"https:\/\/www.tfngj.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#primaryimage"},"image":{"@id":"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp","datePublished":"2025-10-24T01:33:35+00:00","dateModified":"2026-01-22T03:11:33+00:00","description":"Testeur portable de 10 gigabits, permettant des tests \u00e0 plein d\u00e9bit de 10M \u00e0 10G, facilitant le d\u00e9ploiement et la maintenance de r\u00e9seaux \u00e0 haut d\u00e9bit.","breadcrumb":{"@id":"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#primaryimage","url":"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp","contentUrl":"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/10\/back-1-scaled.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.tfngj.com\/ethernet-testers\/t3000a-10-gigabit-ethernet-tester\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tfngj.com\/"},{"@type":"ListItem","position":2,"name":"Ethernet Testers","item":"https:\/\/www.tfngj.com\/ethernet-testers\/"},{"@type":"ListItem","position":3,"name":"T3000A 10 Gigabit Ethernet Tester"}]},{"@type":"WebSite","@id":"https:\/\/www.tfngj.com\/#website","url":"https:\/\/www.tfngj.com\/","name":"TFN - Expert en essais de communication","description":"Trouver des solutions parfaites dans la TFN","publisher":{"@id":"https:\/\/www.tfngj.com\/#organization"},"alternateName":"TFN","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tfngj.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.tfngj.com\/#organization","name":"TFN","url":"https:\/\/www.tfngj.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.tfngj.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/09\/\u9ed1logo.png","contentUrl":"https:\/\/www.tfngj.com\/wp-content\/uploads\/2025\/09\/\u9ed1logo.png","width":939,"height":232,"caption":"TFN"},"image":{"@id":"https:\/\/www.tfngj.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.youtube.com\/@FateTFN\/search"]}]}},"_links":{"self":[{"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/pages\/2740","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/comments?post=2740"}],"version-history":[{"count":28,"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/pages\/2740\/revisions"}],"predecessor-version":[{"id":5761,"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/pages\/2740\/revisions\/5761"}],"up":[{"embeddable":true,"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/pages\/1408"}],"wp:attachment":[{"href":"https:\/\/www.tfngj.com\/fr\/wp-json\/wp\/v2\/media?parent=2740"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}